Please, observe all
warnings.
Disconnect power before removal or lamp replacement. Proper
installation should have UV lamp(s) at right angles to
air flow, centered in duct or plenum. The UV Air Cleanser
can be installed on either supply or return sides, at least
30" away from plastic
air filters, of the coil and is equally effective. Note,
however, if UV lamp is installed close to register or grill,
the ultraviolet light may cause night glow effect which may
be objectionable to homeowner. LAMP
REPLACEMENT
Step-by-Step UV Air Cleanser
Installation Instructions:
- Establish a location,
at least 30" away
from plastic air filters, for installation on the RETURN
or SUPPLY SIDE of the air handling duct system.
- Drill one 1⅜” hole
for the UV emitter lamp.
- Remove the cover and
mount the UV Air Cleaner chassis to the duct.
- Position the unit
on the duct, attach hardware, and tighten the unit in place.
To install
the UV lamp,
slide the UV lamp through the adjustable coupling into
the duct. Attach the plug carefully to the end of the four
prongs of the lamp and mount the base of the lamp flush
with the coupling. CAREFULLY tighten the adjustable coupling
compression cap to clamp the lamp.
- Replace the cover
and tighten the screws. Do not pinch or cut any wires.
- Drill a 7/16” hole in the duct 6 inches away from the mounting
position of the UV-C emitter lamp. Insert the indicator plug in
the hole. When the lamp is lit, the plug will glow as an indicator
that the unit is working correctly. (Do not install the indicator
plug if its glow will be objectionable because of the “night light” effect.)
- Attach the Warning
Label on the duct next to the installed UV Air Cleaner.
- Power the unit by
plugging the standard 120V power cord or hard wire for
220V. The electronic ballast will switch automatically.
UV lamp replacement: requires one HO-14 or
HO-22 germicidal UV lamp, obtained from your dealer.
Important Tips
The High Output UV Air
Cleaner is the strongest UV air cleaner available on the
air-quality market. It requires a minimum of rules for a
productive installation:
- Avoid
direct exposure, at least 30" away from any plastics,
including air filters, drip pans, plastic filter
frames, etc.)
|
- Avoid
ANY location that would permit the homeowner access
to the lamp. (Example: closet door with louvers and
the unit exposed when door is open or light is seen
through the louvers.) Consider night light issue.
|
- Best
location: across top of "A" coil @ right angles to “A”;
also return plenum if not within visible range
of filters, louvers, etc. (A homeowner should not
be able to remove the filter and see or touch the
lamp).
|
- The
High Output UV lamp will provide
strong germicidal protection for 1 year. The
reason - it does not cycle on/off thereby maximizing
its life and efficiency. To keep the UV air cleaner
in top performance range, it is recommended the
UV lamp to be replaced every year.
|
- Review
of the specification sheet and installation instructions
will provide answers to most situations and questions.
|
|